[单项选择]The low pressure side of a refrigeration system is considered to exist from the ().
A. expansion valve to the compressor
B. receiver to the expansion coil
C. expansion valve to the evaporator
D. condenser to the expansion valve

更多"The low pressure side of a refriger"的相关试题:

[单项选择]The refrigeration system low pressure cutout switch is actuated by ().
A. an electric system manager
B. a sensing bulb at the tail coil of the evaporator
C. pressure changes in the suction line
D. failure of the king solenoid valve
[单项选择]The purpose of the refrigeration system low pressure cutout switch is to ()
A. protect the compressor from liquid flood back
B. protect the compressor from low discharge pressure
C. start and stop the compressor upon system demand
D. start the compressor after a drop in the evaporator pressure
[单项选择]In an operating refrigeration system low on refrigerant, a liquid line sight glass will()
A. be clear
B. be blue
C. be light green
D. show bubbles
[单项选择]What separate the high pressure side from the low pressure side in a refrigeration system?()
A. Condenser and thermal expansion valve
B. King and solenoid valves
C. Compressor and thermal expansion valve
D. Condenser and solenoid valve
[单项选择]Compared to a low pressure system,generally the air in a high is().
A. warmer,less dense,and less stable
B. cool,more dense,and drier
C. muggy and cloudy
D. extremely moist with high relative humidity
[单项选择]The passing of a low pressure system can be determined by periodically checking the().
A. Thermometer
B. Hygrometer
C. Barometer
D. Anemometer
[单项选择]In an air conditioning system, low head pressure associated with a reciprocating compressor can be the result of ()
A. broken valve springs
B. tight drive belts
C. high line voltage
D. air in the system
[单项选择]Low compressor head pressure in a refrigeration system can be caused by().
A. insufficient condenser cooling water
B. excessive condenser cooling water
C. air in the refrigeration system
D. excessive refrigerant in the system
[单项选择]Refrigeration system compressor crankcase sweating is an indication of ().
A. insufficient lube oil circulating through the system
B. excessive circulation of lube oil through the system
C. insufficient refrigerant in the system
D. an overworked compressor
[单项选择]A refrigeration system contaminated with moisture can be affected by ().
A. acid formation
B. sludge formation
C. ice in the expansion valve
D. All of the above
[单项选择]As a high pressure system approaches,the barometer reading().
A. stays the same
B. falls
C. rises
D. falls rapidly
[单项选择]A refrigeration system compressor crankcase is sweating or unusually coldThis is an indication of().
A. a shortage of refrigerant in the system
B. air in the system
C. an accumulation of liquid refrigerant in the crankcase
D. a shortage of oil in the crankcase
[单项选择]Which of the listed refrigeration system components keeps the refrigerant circulating through the system?()
A. Expansion valve
B. Condenser
C. Evaporator
D. Compressor
[单项选择]While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().
A. change the expansion valve adjustment
B. readjust the water regulating valve to increase the flow of water
C. purge air from the condenser
D. clean the waterside of the condenser
[单项选择]If a refrigeration system compressor crankcase is sweating, you should ().
A. add refrigerant to the system
B. adjust the thermal expansion valve to the proper setting
C. adjust the float valve to the proper holding pressure
D. open the hand expansion valve
[单项选择]Sweating of the refrigeration system compressor crankcase is caused by ().
A. too much superheat
B. insufficient superheat
C. suction pressure too low
D. excessive refrigerant returning to the compressor
[单项选择]When a high pressure system is centered north of your vessel in the Northern Hemisphere().
A. You should experience hot,moist,clear weather
B. The wind direction is generally easterly
C. The winds should be from the southwest at your location
D. The winds should be brisk
[单项选择]High pressure and low pressure alarms must be tested().
A. no earlier than 24 hours prior to loading
B. no later than 24 hours prior to loading
C. anytime prior to loading
D. weekly

我来回答:

购买搜题卡查看答案
[会员特权] 开通VIP, 查看 全部题目答案
[会员特权] 享免全部广告特权
推荐91天
¥36.8
¥80元
31天
¥20.8
¥40元
365天
¥88.8
¥188元
请选择支付方式
  • 微信支付
  • 支付宝支付
点击支付即表示同意并接受了《购买须知》
立即支付 系统将自动为您注册账号
请使用微信扫码支付

订单号:

请不要关闭本页面,支付完成后请点击【支付完成】按钮
恭喜您,购买搜题卡成功
重要提示:请拍照或截图保存账号密码!
我要搜题网官网:https://www.woyaosouti.com
我已记住账号密码