[单项选择]The refrigeration system low pressure cutout switch is actuated by ().
A. an electric system manager
B. a sensing bulb at the tail coil of the evaporator
C. pressure changes in the suction line
D. failure of the king solenoid valve
[单项选择]The passing of a low pressure system can be determined by periodically checking the().
A. Thermometer
B. Hygrometer
C. Barometer
D. Anemometer
[单项选择]High pressure and low pressure alarms must be tested().
A. no earlier than 24 hours prior to loading
B. no later than 24 hours prior to loading
C. anytime prior to loading
D. weekly
[单项选择]In an air conditioning system, low head pressure associated with a reciprocating compressor can be the result of ()
A. broken valve springs
B. tight drive belts
C. high line voltage
D. air in the system
[单项选择]The low pressure side of a refrigeration system is considered to exist from the ().
A. expansion valve to the compressor
B. receiver to the expansion coil
C. expansion valve to the evaporator
D. condenser to the expansion valve
[单项选择]As a high pressure system approaches,the barometer reading().
A. stays the same
B. falls
C. rises
D. falls rapidly
[单项选择]When a high pressure system is centered north of your vessel in the Northern Hemisphere().
A. You should experience hot,moist,clear weather
B. The wind direction is generally easterly
C. The winds should be from the southwest at your location
D. The winds should be brisk
[单项选择]The purpose of the refrigeration system low pressure cutout switch is to ()
A. protect the compressor from liquid flood back
B. protect the compressor from low discharge pressure
C. start and stop the compressor upon system demand
D. start the compressor after a drop in the evaporator pressure
[单项选择]In an operating refrigeration system low on refrigerant, a liquid line sight glass will()
A. be clear
B. be blue
C. be light green
D. show bubbles
[单项选择]High cylinder firing pressure, accompanied by low exhaust temperature, can result from ()
A. improper fuel rack positing
B. lengthy exhaust valve duration
C. extend operation at light load
D. excessively early injection timing
[单项选择]What separate the high pressure side from the low pressure side in a refrigeration system?()
A. Condenser and thermal expansion valve
B. King and solenoid valves
C. Compressor and thermal expansion valve
D. Condenser and solenoid valve
[单项选择]The primary reason low pressure evaporators produce distillate more efficiently, and with less scale formation, than high pressure evaporators is ().
A. evaporation is accomplished in a vacuum
B. due to the higher temperature of the incoming feed
C. due to the latent heat of evaporation principle
D. evaporation in a submerged medium produces more distillate
[单项选择]In the () pressure charging system the pulse of energy that occur as the exhaust is released from the cylinder to improve the output of the turbocharger.
A. constant
B. pulse
C. high
D. none of the above
[单项选择]Excessively low air pressure occurring in the intercooler of a reciprocating air compressor is caused by().
A. leaky discharge valves on the LP cylinder
B. leaky discharge valves on the HP cylinder
C. insufficient intercooler cooling
D. low ambient air pressure
[单项选择]Low cylinder compression pressure and a high exhaust temperature may indicate ()
A. early fuel injection timing
B. leaking valves
C. a continuously open scavenge air port
D. low cooling water temperature
[单项选择]Low compressor head pressure in a refrigeration system can be caused by().
A. insufficient condenser cooling water
B. excessive condenser cooling water
C. air in the refrigeration system
D. excessive refrigerant in the system
[单项选择]In the Southern Hemisphere winds in a low pressure system rotate in a().
A. clockwise direction
B. northeasterly direction
C. northerly direction
D. counterclockwise direction
[单项选择]The circulation around a low pressure center in the Northern Hemisphere is().
A. counterclockwise
B. variable
C. clockwise
D. anticyclonic